Table 1 Pulse sequence parameters from the Digital Imagining and Communications in Medicine (DICOM) data for each of the modalities used

From: Simulation of semilunar valve function: computer-aided design, 3D printing and flow assessment with MR

 

Scan duration (minutes)

2D/ 3D

In-plane resolution (mm2)

Slice thickness (mm)

TR/TE (ms)

Field of View

Matrix size

Flip angle (°)

Venc (cm/s)

4D Flow

11.7 (in-plane GRAPPA acceleration factor = 3)

3D

1.6 × 1.6

1.6

48.6/3.5

200 × 156 × 64 mm3

128 × 102 × 40

7

100

Phase Contrast

0.5

2D

1.0 × 1.0

5 (single slice acquisition)

50.9/4.1

200 × 119 mm2

192 × 116

25

70

Cine (axial)

1.5

2D

1.0 × 1.2

3 (5 slices acquired)

58.8/3.3

200 × 119 mm2

192 × 99

12

n/a

Cine (coronal)

1.5

2D

1.2 × 1.3

3 (3 slices acquired)

57.5/3.3

224 × 133 mm2

192 × 99

12

n/a