Skip to main content

Table 4 The 5 most weighted (W) optimal treatment combinations for the LAA model

From: A focused simulation-based optimization of print time and material usage with respect to orientation, layer height and support settings for multi-pathological anatomical models in inverted vat photopolymerization 3D printing

ORN (Deg)

LH (mm)

SD

STS (mm)

MU (mL)

PT (min)

W

45

0.1

0.8

0.5

53.21

454

−0.9639

45

0.1

0.8

0.4

54.05

456

−0.9409

15

0.1

0.8

0.5

51.24

472

−0.9314

15

0.1

0.8

0.4

51.35

476

−0.9141

30

0.1

0.8

0.5

54.47

480

−0.8417