Table 4 Recommended design parameters for distensible arteries

From: Compliant vascular models 3D printed with the Stratasys J750: a direct characterization of model distensibility using intravascular ultrasound

Vessel Type

Inner Diameter [mm]

Wall Thickness [mm]

Material

Aorta

30

3

Compliant, Slightly Compliant

Carotid

9

1.5

Compliant, Slightly Compliant

Coronary

3

1

Slightly Compliant, Rigid