Skip to main content

Table 2 Artifact Volume and segmentation time for 4 patients referred for head-and-neck acquisition and reconstructed with and without iterative metal artifact reconstruction. Only one patient was acquired with a jaw spacer, whereas none of the acquisitions were performed with a tilted gantry

From: Implementation of iterative metal artifact reduction in the pre-planning-procedure of three-dimensional physical modeling

Patient

Iterative MAR

Artifact Volume [ml]

Segmentation time [s]

Jaw spacer

1

No

36

340

No

Yes

5.6

200

2

No

4.5

150

No

Yes

4.5

135

3

No

36

300

No

Yes

3.3

180

4

No

6.7

310

Yes

Yes

3.4

101