Table 3 STL measurement rubric consisting of the rating scales and their descriptions for the image quality measurement of the STLs

From: Stereolithography (STL) measurement rubric for the evaluation of craniomaxillofacial STLs

Evaluation item

Qualitative measurement rating scale

Poor visual acuity

Rating = 1

Partial visual acuity

Rating = 2

Good visual acuity

Rating = 3

1. Cranial sutures

Cranial sutures demonstrate poor visual acuity and appear to be smooth.

Cranial sutures demonstrate partial visual acuity and appear to have some definition but still unclear.

Cranial sutures demonstrate good visual acuity and appear clearly defined.

2. Head of the mandible

Head of the mandible demonstrates poor visual acuity and does not show clear delineation of the different individual anatomical structures.

Head of the mandible demonstrates partial visual acuity and shows some delineation of the different individual anatomical structures but not clearly.

Head of the mandible demonstrates good visual acuity shows clear delineation of the different individual anatomical structures.

3. Temporomandibular fossa separation

The boundary between the fossa and the adjacent skull demonstrates poor visual acuity.

No clear delineation exists between the margins of the fossa and adjacent anatomical structures.

The boundary between the fossa and the adjacent skull demonstrates partial visual acuity.

Incomplete separation exists between the margins of the fossa and adjacent anatomical structures.

The boundary between the fossa and the adjacent skull demonstrates good visual acuity.

Complete and clear separation exists between the margins of the fossa and adjacent anatomical structures.

4. Supraorbital foramina

Supraorbital foramina demonstrate poor visual acuity and are not clearly delineated.

Supraorbital foramina demonstrate partial visual acuity and are partially delineated.

Supraorbital foramina demonstrate good visual acuity and are clearly delineated.

5. Infraorbital foramina

Infraorbital foramina demonstrate poor visual acuity and are not clearly delineated.

Infraorbital foramina demonstrate partial visual acuity and are partially delineated.

Infraorbital foramina demonstrate good visual acuity and are clearly delineated.

6. Mental foramina

Mental foramina demonstrate poor visual acuity and are not clearly delineated.

Mental foramina demonstrate partial visual acuity and are partially delineated.

Mental foramina demonstrate good visual acuity and are clearly delineated.

7. Teeth

Individual teeth demonstrate poor visual acuity.

Poor discrimination between individual teeth.

Individual teeth demonstrate partial visual acuity.

Partial discrimination between individual teeth.

Individual teeth demonstrate good visual acuity.

Good discrimination between individual teeth.

8. Mandibular canal (inferior alveolar nerve)

The mandibular canal demonstrates poor visual acuity and is not clearly delineated.

The mandibular canal demonstrates partial visual acuity and is partially delineated.

The mandibular canal demonstrates good visual acuity and is clearly delineated.

9. Concentric rings visible (rings score)

Present = 0

Absent = 3

 

10. Overall impression of the designer

STL poses relative difficulty in the design of the prosthesis.

STL poses some difficulty in the design of the prosthesis.

STL poses no difficulty in the design of the prosthesis.